| SPECIFICATIONS | AD-C6T | 
| Effective frequency range1 | 63 Hz – 20 kHz | 
| Rated noise power / voltage2 | 60 watts / 31 volts (rms) | 
| Sensitivity [dB]3 Sensitivity at 4m,  | 88 TBD | 
| Rated coverage (-6 dB)4 Coverage angle by frequency Conical coverage | 140° conical DMT 
 
 | 
| One-third octave frequency band contribution at full power using 100V maximum tap (Hz / dB) | 100V maximum tap (Hz / dB) 500 / 57.4; 630 / 57.4; 800 / 57.4 1000 / 57.4; 1250 / 57.4; 1600 / 57.4 2000 / 57.4; 2500 / 57.4; 3150 / 57.4 4000 / 57.4 | 
| Directivity factor (Q)4 | 6.5 | 
| Directivity index (DI) [dB]4 | 8 | 
| Maximum continuous SPL [dB]5 | 106 | 
| Maximum peak SPL [dB]5 | 112 | 
| Nominal impedance [ohms] | 16 | 
| Recommended amplifier | 120 watts | 
| Transformer taps / impedance | 16Ω (in bypass setting) 7.5W (70V); 15W (100V) Tap: 667Ω 15W (70V); 30W (100V) Tap: 333Ω 30W (70V); 60W (100V) Tap: 167Ω 60W (70V); N/A (100V) Tap: 83Ω | 
| LF transducer | 165 mm [6.5 in] weather resistant paper cone woofer | 
| HF transducer | 25 mm [1 in] aluminum dome tweeter | 
| Input connector type | Euroblock connector with parallel output | 
| Enclosure material | ABS baffle on powder coated steel back can | 
| Grille material | Powder coated steel | 
| Ingress protection | IP-54 | 
| Operating environment | Designed for indoor use | 
| Operating temperature range | -20 to 50° C [-4 to 122° F] | 
| Cutout dimension | Ø 245 mm [Ø 9.65 in] | 
| Net weight | 4.3 kg [9.5 lb] | 
| Product dimensions (Diameter x Height) | Ø 280 x 237 mm [Ø 11.02 x 9.32 in.] | 
| Shipping weight | 12.6 kg [27.8 lb] (pair packed) | 
| Shipping dimensions (H x W x D) | 330 x 737 x 381 mm [13 x 29 x 15 in] (pair packed) | 
| Included accessories | C-ring and tile rails, rail screws, euroblock connector, cut-out template, grille | 
| Optional accessories | AD-MR4 (pre-install mud ring) AD-CC4 (pre-install conduit cover) | 
| Safety Agency | EN54-24: 2008 type A (No. pending) UL1480, UL2043, NFPA90, NFPA70 suitable for use in air handling spaces. Transformer UL registered per UL1876, ROHS, C-Tick X000, CE compliant. Baffle meets UL94-V0 and UL94-5VB flammability rating; in accordance with IEC60849 / EN60849 systems. | 
1Half Space, -10dB from on-axis sensitivity 
2IEC60268-5 50hz high passed noise at 2 Hrs, 16?
3 Free-field, on-axis, 2.83V, 1m
4-6 dB from on-axis, 500 Hz–5 kHz average
5Calculated from rated noise voltage and sensitivity