RMX 5050a adalah power amplifier 2 channel dengan performa berkualitas profesional yang menggabungkan desain-desain QSC yang sudah terbukti kehandalannya. 3RU 2-CH 1600W @ 4 ohms
| Power per Channel, Stereo Mode (both channels driven) | |||
| 8Ω, FTC 20 Hz–20 kHz, 0.1% tdD | 1050 W | ||
| 8Ω, EIA 1 kHz, 0.1% tdD | 1100 W | ||
| 4Ω, FTC 20 Hz–20 kHz, 0.1% tdD | 1600 W | ||
| 4Ω, EIA 1 kHz, 0.1% tdD | 1800 W | ||
| 2Ω, FTC 20 Hz–20 kHz, 1% tdD | 2000 W | ||
| 2Ω, EIA 1 kHz, 1% tdD | 2500 W | ||
| Power, Bridge-Mono Mode | |||
| 8Ω, FTC 20 Hz–20 kHz, 0.1% tdD | 3200 W | ||
| 8Ω, EIA 1 kHz, 0.1% tdD | 3600 W | ||
| 4Ω, EIA 1 kHz, 1% tdD | 5000 W | ||
| Signal to Noise (20 Hz–20 kHz) | -100 dB | ||
| Distortion (SMPTE-IM) | < 0.02% | ||
| Input Sensitivity at 8Ω | 1.42V (+5.3 dBu) | ||
| Voltage Gain | 64x (36 dB) | ||
| Output Circuitry | 3-tier Class H | ||
| Current Draw (120 V AC) Typical, 1/8 power pink noise at 4Ω* Severe, 1/3 power pink noise at 4Ω* |
13.9 A 26.9 A |
||
| AC Mains Plug 100/120V 230V |
NEMA 5-20 |
||
| Weight Net Shipping |
75 lb (33.1 kg) 87 lb (37.2 kg) |
||
| Distortion (typical) 20 Hz–20 kHz, 10 dB below rated power 1 kHz and below, full rated power |
< 0.02% tdD, 4Ω and 8Ω < 0.02% tdD, 4Ω and 8Ω |
||
| Frequency Response | 20 Hz–20 kHz: +0/-1 dB -3 dB points: 5 Hz and 50 kHz (LF filter bybassed, 8Ω) | ||
| Damping Factor (1 kHz and below) | > 250 at 8Ω | ||
| Input Impedance | 10 kΩ unbalanced; 20 kΩ balanced | ||
| Input Stage Clipping | 6.4 V rms (+18 dBu) | ||
| Cooling | Continuously variable speed fan, back-to-front air flow | ||
| Connectors (each channel) | Input: Active balanced; 3-pin Euro-style detachable terminal block and XLR (pin 2+) Output: Touch-proof binding posts; Neutrik Speakon® |
||
| Controls | Front: AC switch; Channel 1 & 2 gain knobs Rear: 10-position DIP switch |
||
| LED Indicators | Power on: Green; Signal: Yellow (1 per channel); Clip/Protect: Red (1 per channel) | ||
| Amplifier Protection | Full short circuit, open circuit, tdermal, ultrasonic, RF protection. Stable into reactive or mismatched loads | ||
| Load Protection | Turn-on/off muting; AC coupling (850, 1450); Triac crowbar (1850HD, 2450, 4050HD, 5050) on each channel | ||
| Dimensions | 5.25” (13.3 cm) tall; 3 rack spaces | ||
| Power Requirements | 100, 120, 230 V AC (factory configured), 50–60 Hz | ||